Quantcast
Channel: SCN: Message List - PowerBuilder Developer Center
Browsing all 7329 articles
Browse latest View live

Re: select all checkbox at header column of data window

I would use a Button control and put code in the buttonclicked event to select all rows.

View Article


Re: select all checkbox at header column of data window

Hi Mahesh;   The only place you can emulate a check box is on a column using the Edit Style feature. Unfortunately, this only works for data input when the column resides in the Detail Band. Moving any...

View Article


Image may be NSFW.
Clik here to view.

Re: PB 12.6 (build 3506) Application Exit Codes

Hi Doug;    Have you tested your application with a DOS command file to see if PB 12.6 is actually returning an exit code properly? I am wondering here if the problem is PB 12.6 vs NSSM.   FYI:...

View Article

Re: PB 12.6 (build 3506) Application Exit Codes

I am sorry if I somehow led you to think NSSM is the problem.  It's not, PowerBuilder is. The PROBLEM restated for clarity: In earlier versions of PowerBuilder I could add code to the application close...

View Article

Re: select all checkbox at header column of data window

You can use Wingdings 2 font (if that is applicable to you) to mimick a check box at your header column. Alternately change the character to display as checked or unchecked at the click event of the...

View Article


Re: PB 12.6 (build 3506) Application Exit Codes

You should report that as a bug so they can fix it.

View Article

Re: PB 12.6 (build 3506) Application Exit Codes

Exactly ... that is why I asked if you had made a simple test with PB 12.6 and a DOS Command batch file (link the link I posted) to see if a PB 12.6 application was indeed still returning a proper DOS...

View Article

Re: select all checkbox at header column of data window

You can still place a column in the header band and make it edit style check box. You will need to set/reset the value of the column in the clicked event as it will appear disabled to the user. The...

View Article


Re: PB 12.6 (build 3506) Application Exit Codes

That is weird as whether I open a Window class or not the Close event setting is passed back OK to the O/S. The only reason I could think of for your test not working - is if the Window Class you are...

View Article


Re: PB 12.6 (build 3506) Application Exit Codes

Oh wonderful.. a whole new facet to the puzzle, I thought you had not been opening a window object. No.. I'm not using a halt. It's the standard generated menu, so it's just doing a Close(...

View Article

Re: Getting error response while trying to access REST webservice through...

Hi ,, Can anybody have any thoughts on this.  RegardsSubrat

View Article

Re: PB 12.6 (build 3506) Application Exit Codes

I've got to have something highly odd going on. Just made a new application, didn't generate anything. Added new project and a new window (main!) objects. Opens window, close window, value is set just...

View Article

Re: PB 12.6 (build 3506) Application Exit Codes

A Windows Service app should not be opening a window. A Windows Service program runs in the background 24/7, even when there is not a user logged into the computer. Having a service app open a window...

View Article


Re: PB 12.6 (build 3506) Application Exit Codes

Thanks.. I'm aware of that. I didn't design it, I just inherited it. And I really doubt I'm getting sign off to rewrite it. And.. apparently Message.LongParm will work even if the application does open...

View Article

Re: Problem with Powerbuilder MAPI / Mozilla Thunderbird / Tobit David

Stefan, The CR I opened, 781930 for this issue has been fixed.I am not sure when the next EBF will be posted for customers but the fix should be included in the next EBF. Pat

View Article


Re: Getting error response while trying to access REST webservice through...

Hi Subrata;   Have you tried running something like Fiddler2 to see exactly what the WS exchange & eventual failure might be? FYI: Fiddler free web debugging proxy Regards ... Chris

View Article

Why is datawindow retrieval in Window so much slower than Datawindow painter?

I am using PB 12.5. The problem is my datawindow that uses a stored procedure as a data source runs in 2-3 seconds in the Datawindow painter.  However, when the window runs the data retrieval takes...

View Article


Re: Why is datawindow retrieval in Window so much slower than Datawindow...

Are the database connection settings the same in IDE and applications?Try to trace the database activities with IDS and application to find differences. SyBooks Online (Archive)

View Article

Re: datastore print with WCF

Thanks Andreas,   I should have mentioned that my return code returns 10 which is exactly how many rows I am expecting.   So I think that proves that there is no problem connecting to the database and...

View Article

Re: datastore print with WCF

Hi Ephraim;  I suspect that your problem is related to a privileges issue. I suspect that II's internal user (IIs_User) does not have access to the PDF printer.  The other alternative is to associate...

View Article
Browsing all 7329 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>